Chart’nX: KNX data visualization, metering and export
Chart’nX is the Can’nX tool for KNX data visualization and analysis. Its dashboards, for energy or water, open from Emergy’nX or from Boss’nX. The guides cover viewing and exporting measurements, then configuring dashboards: KNX or Modbus meters, groups, calculations and address monitoring.
Getting started
Section titled “Getting started”- From Emergy’nX, open the Chart’nX section and choose the dashboard: View displays the charts, Configure opens its generator. New dashboard opens the generator on a new energy dashboard. See open Chart’nX from Emergy’nX.
- From Boss’nX, open Analyses, then the Chart’nX tab, with the View analytics permission. This entry presents the existing dashboards, without a creation command. See open Chart’nX from Boss’nX.
Main tasks
Section titled “Main tasks”View and export
- Set the period and precision, then read the charts in the Unified, Stacked, Curves or Per phase presentation, depending on the panel.
- Read phase measurements and set the time zone, language, units and axes.
- Export the data as an Excel report, a CSV suited to spreadsheets, or as Raw data for data processing. Several files are grouped in a ZIP archive. The export does not require switching to administration; the format guide details the content of the files.
Configure an energy dashboard
From the generator opened in Emergy’nX:
- Fill in the general information: name, contract power in kVA, single-phase or three-phase installation.
- Configure the main meters, then the submeters, their groups and the total energy calculation.
- Preview and save the dashboard.
- If addresses remain to be monitored, assign them to the monitoring gateways, with the project’s ETS file.
Monitor water
A water dashboard is configured with its general information and the total meter, then its meter groups.
Integrate Modbus meters
The Modbus catalog belongs to the project: a configuration can be used by several dashboards. Create the Modbus gateway, declare the configuration, test the reading, then import it as a submeter.
Troubleshooting
Section titled “Troubleshooting”- Viewing dashboards and CSV export.
- Meter configuration and address monitoring.
- Water dashboard and Modbus catalog.
See also Energy and metering, Water metering and Modbus.
All Chart’nX guides
Section titled “All Chart’nX guides”Access and getting started
Section titled “Access and getting started”- Open a Chart’nX dashboard from the Boss’nX Analytics page
- Open or create a Chart’nX dashboard from Emergy’nX
Configuration and use
Section titled “Configuration and use”- Chart’nX battery meter: energy and state of charge over KNX or Modbus
- Time zone, language, unit and Y scale in Chart’nX
- Export data from a Chart’nX dashboard to a CSV file
- Chart’nX CSV export: choose the format and read the file
- Chart’nX export labels: French and English equivalents
- Chart’nX energy dashboard: name, power in kVA and phases
- Group submeters and set the display order in Chart’nX
- Overlay temperature or presence on a Chart’nX meter chart
- Configure the L1, L2 and L3 phases of a three-phase Chart’nX meter
- Configure the KNX or Modbus main meters of a Chart’nX dashboard
- Total energy in Chart’nX: add and subtract meters
- Set the period and precision of a Chart’nX dashboard
- Read per-phase current and phase imbalance in Chart’nX
- Read the charts of a Chart’nX dashboard and change their presentation
- Save a Chart’nX dashboard: preview, save and close the generator
- Add, duplicate or delete a Chart’nX energy submeter
- Set up a Chart’nX water dashboard: name, presence and total meter
- Create a Chart’nX water meter group: primary and secondary meters
- Organize, duplicate or remove the cards of a Chart’nX water dashboard
- Calculate a sum or difference of water meters in Chart’nX
Protocols, imports and monitoring
Section titled “Protocols, imports and monitoring”- Archive, restore or delete a Modbus configuration in Chart’nX
- Chart’nX Modbus catalog: find a meter configuration
- Declare, edit or duplicate a Modbus configuration in Chart’nX
- Create, edit or disable a Modbus gateway in Chart’nX
- Import Modbus configurations as Chart’nX submeters
- Test a Modbus reading in Chart’nX: result and unavailable test
- Assign KNX addresses to monitoring gateways in Chart’nX
Questions and troubleshooting
Section titled “Questions and troubleshooting”- Chart’nX CSV export: missing button, missing panel or failure
- Chart’nX dashboards: frequently asked questions about viewing
- Chart’nX energy meter: troubleshooting and frequently asked questions
- Modbus in Chart’nX: missing measurements and frequently asked questions
- Troubleshoot KNX address monitoring in Chart’nX
- Chart’nX water dashboard: troubleshooting and frequently asked questions