With Link’nX, the relays, covers and lights of a Shelly device are controlled from the KNX bus: on/off, toggle, open, stop, position and brightness. Its states and measurements (relay and light state, power, energy, cover position, device temperature) can be read back by the bus. Link’nX reaches the device locally, through its IPv4 address and port.
What the Shelly integration does
Section titled “What the Shelly integration does”| Need | Where to configure it | Guide |
|---|---|---|
| Control a relay or a light from a KNX button | Gateway table, Actions tab | Map relays, covers and lights to KNX |
| Raise, lower, stop or position a cover | Cover rows of the Actions tab | Map relays, covers and lights to KNX |
| Read a relay’s state, power or energy | Gateway table, second tab | Shelly status feedback and measurements |
| Read a cover’s position or a light’s brightness | Gateway table, second tab | Shelly status feedback and measurements |
| Control the device in a scenario | KNX action on the mapped address | Prepare a KNX action |
Step-by-step commissioning
Section titled “Step-by-step commissioning”- Identify the device’s model, generation, mode and channels, as well as its local access credentials.
- Declare the device in Smart Home → Shelly: name, IPv4 address, port (80 by default) and credentials if access is protected.
- Map its commands to KNX group addresses in the Actions tab of the gateway table.
- Map its status feedback and measurements in the second tab.
- Send each command from the bus, for example with the ETS group monitor, and watch the device.
If something goes wrong, the Shelly feedback guide covers commands with no effect, a channel that does not respond, a missing position and energy that seems a thousand times too high.
Good to know
Section titled “Good to know”- For a protected Gen2 or Gen3 device, the username is admin; for a Gen1, use the credentials of its local access. Have a Gen1 cover or dimmer validated by support.
- The table offers the same rows for every model (relays 0 to 3, covers 0 and 1, lights 0 and 1): only activate the channels the device actually has.
- The toggle (DPT 1.017) inverts the state on each telegram, including 0: a button that sends on press and on release causes two inversions.
- The cover position (DPT 5.001) follows the KNX convention: 0 = open, 100 = closed. Power is in W (DPT 14.056), energy in Wh (DPT 13.010).
- There is no dedicated Shelly action type or trigger: a scenario controls the device through a KNX action on the mapped address.
For other lighting and shutter controls, see Lighting, blinds and shutters.
All Shelly guides
Section titled “All Shelly guides”Devices and integrations
Section titled “Devices and integrations”- Add a Shelly device in Link’nX: IP address, port and credentials
- Shelly and KNX: status feedback, measurements and troubleshooting