Skip to content

Chart’nX Modbus catalog: find a meter configuration

Chart’nXAdministratorInstaller

Chart’nX energy or water generator: project Modbus catalog, Active and Archived tabs

The Chart’nX Modbus catalog gathers, for the whole project, the Modbus gateways and the configurations that tell each meter which register to read. The same configuration can be used by several energy or water dashboards.

Intended for administrators and installers who configure a dashboard in the Chart’nX generator. To create an entry, follow Declare a Modbus configuration instead.

  1. Open the dashboard configuration as described in the Emergy’nX entry point and wait until the form is available.
  2. In the top bar, click Modbus catalog. On a narrow screen, the text may be hidden: look for the stacked-cylinder icon with the Modbus catalog tooltip.
  3. To return to the dashboard, click Close.
  1. In Active, expand the gateway with the chevron to the left of its name. The group header shows the IP address and port, as well as the associated Can’nX gateway when it is available.
  2. Locate the configuration by its name and its U markers for the unit and R for the register.
  3. To filter the list, type its name, its unit ID or its register address in Search a configuration or a gateway. Clear the search to see all the gateways again, including those without a configuration.
  4. In a long list, use the shortcuts bearing the group names to move around.
  5. For a configuration that has been stopped and kept, choose Archived. The … counter means that the number is not yet available; it is not zero.

The actions of a row appear on its right and depend on the tab.

TabActionGuide
ActiveTest readTest a Modbus reading
ActiveDuplicate (two squares), Edit configuration (pencil)Declare a Modbus configuration
ActiveArchive (box)Archive or delete Modbus items
ArchivedRestore (return arrow), Delete permanently (trash)Archive or delete Modbus items

The buttons in a gateway header apply to all its configurations, as described in the Modbus gateway guide. Always check whether you are acting on a row or on its header.

A catalog entry only appears on a dashboard once it is selected in a meter or imported as a submeter. Close cancels nothing: changes already confirmed in the catalog are kept, independently of saving the dashboard.

If your configuration seems to be missing, check the project, clear the filter, check the tab, expand the group, then look in Archived.

MessageMeaningAction
No configuration matches your search.The filter finds no entryClear or correct the search
No Modbus configuration in this project yet.The active list is empty without a filterCheck the project, then Archived
Could not refresh the catalogReloading failed; it does not allow you to conclude that the configurations have disappearedClose and reopen the catalog once

If the message persists, contact support@can-nx.com with the project, the tab and the message, without any secret identifier.

French labels: Catalogue Modbus, Actives, Archivées, Gérer le catalogue.