Pool’nXAdministratorInstaller

Pool’nX with a PoolCop: Pool Status and Pool Commands tables, PoolCop Cloud and legacy

This reference table lists the statuses that a Pool’nX reads on a PoolCop through PoolCop Cloud and the commands it passes on to it from the KNX bus: displayed name, key, DPT, unit and coded values for the pump, valve, water level and alarms. A last section sums up the PoolCop (legacy) type.

Intended for the installer who prepares the KNX objects, the visualization or the logic of the pool. The procedure for entering addresses is described in the KNX statuses and the KNX commands. The key is also used by the TCP client.

Temperatures, pressures, volumes and flow rates are sent in the units of the PoolCop account, with no conversion: the Value column shows the unit used, for example °C or °F, bar, kPa or psi, m³ or gal. Check that it matches the unit expected by the DPT of the KNX object.

The states of the pump, valve and water level are coded as numbers (DPT 5.010). The Value column shows the PoolCop term followed by the number, for example Speed2 (2).

ValueSpeedValve positionRunning statusFiltration modeWater level
0NoneFilterStoppedStopFaulty
1Speed1WasteFreezeProtectionTimerLow
2Speed2ClosedForcedModeEcoPlusNormal
3Speed3BackwashEcoPlusModeVolumeHigh
4Speed4BypassTimerModeContinuousVeryHigh
5Speed5RinseManualForced24H–
6Speed6–PausedForced48H–
7Speed7–ExternalRequestForced72H–
8Speed8–WaterLevelManagementMode24H–
9––Mode24HNoPump–

The Speed column also applies to Pump number of speeds; the Water level column, to the water level setpoints.

PoolCop Cloud statuses sent on the KNX bus

Section titled “PoolCop Cloud statuses sent on the KNX bus”
NameKeyDPTUnit or value
Water temperature, Air temperaturetempWater, tempAir9.001account temperature
pHpH9.002pH
ORPorp14.027mV
Free chlorine, Free available chlorine, Total chlorinefreeChlorine, freeAvailableChlorine, totalChlorine9.001mg/l
Saltsalt9.001g/l
Pressurepressure9.001pump 1 pressure, account unit
Battery voltage, Mains voltagebattery, mainsVoltage14.027V, 0 if not provided
Service mode, pH dosing, Disinfection dosingserviceMode, pHDosing, disinfectionDosing1.0011: active
Pool connected to the networkpoolConnected1.0011: connected
Pump Status, Pump 2 statuspumpStatus, pump2Status1.0011: running
Pump speed, Pump 2 speedpumpSpeed, pump2Speed5.0100 to 8
Pump pressure, Pump 2 pressurepumpPressure, pump2Pressure9.001account unit
Position of the valve, Pump 2 valve positionvalvePosition, pump2ValvePosition5.0100 to 5
Pump running status, Pump 2 running statuspumpRunningStatus, pump2RunningStatus5.0100 to 9
Pump forced time remaining, Pump 2 forced time remainingpumpForcedRemaining, pump2ForcedRemaining7.005s
Pump number of speeds, Pump 2 number of speedspumpNumberOfSpeeds, pump2NumberOfSpeeds5.0100 to 8
Pump filtration mode, Pump 2 filtration modepumpFiltrationMode, pump2FiltrationMode5.0100 to 9
Water levelwaterLevel5.0100 to 4
Water level setpoint, Water level target setpointwaterLevelSetPoint, waterLevelTargetSetpoint5.0100 to 4
Water level sensor installed, Water level on target, Water level error, Water level refilling, Water level measuringwaterLevelInstalled, waterLevelOnTarget, waterLevelOnError, waterLevelRefilling, waterLevelMeasuring1.0011: yes
Cover installed, Cover controllable, Cover open, Cover closing, Cover opening, Cover stoppedcoverInstalled, coverControllable, coverOpen, coverClosing, coverOpening, coverStopped1.0011: yes
Jet stream installed, Jet stream runningjetStreamInstalled, jetStreamRunning1.0011: yes
Flow meter 1 installed, Flow meter 2 installedflow1Installed, flow2Installed1.0011: yes
Flow rate 1, Flow rate 2flow1Rate, flow2Rate9.001account flow rate
Input 1 to Input 12input1 to input121.0011: active
Auxiliary 1 to Auxiliary 30aux1 to aux301.0011: running
pH setpoint, pH low, pH highpHSetpoint, pHLow, pHHigh9.002pH
ORP setpoint, ORP low, ORP highorpSetpoint, orpLow, orpHigh14.027mV
FAC setpoint, FAC low, FAC highFACSetpoint, FACLow, FACHigh9.001mg/l
FC setpoint, TC low, TC highFCSetpoint, TCLow, TCHigh9.001mg/l
Heating setpointheatingSetpoint9.001account temperature
Pool volumepoolVolume9.001account volume
Freeze protection, ACO installed, Remnant installedfreezeProtection, acoInstalled, remnantInstalled1.0011: yes
Electrolyser productionelectrolyserProductionPercent5.001%
Last backwash (date), Last refill (date), Last pH measurement (date)backwashDate, refillDate, phMeasureDate11.001date
pH sensor present, ORP sensor present, Air temperature sensor present, FAC sensor present, Conductivity sensor present, Salt sensor present, Water level sensor present, FC sensor present, TC sensor present, Flow meter present, Energy meter present, Pool cover present, Jet stream presenthasPHSensor, hasORPSensor, hasAirTemperatureSensor, hasFACSensor, hasConductivitySensor, hasSaltSensor, hasWaterLevelSensor, hasFCSensor, hasTCSensor, hasFlowMeter, hasEnergyMeter, hasPoolCover, hasJetStream1.0011: present
Alertalert1.0011: at least one alarm
Alert numberalertCount5.010number of alarms
Alert 1 to Alert 5alert1 to alert55.010numbered alarm code

The Heating setpoint status takes the setpoint of the first auxiliary that controls heating.

For Auxiliary 1 to Auxiliary 30, the Value column of the statuses shows the auxiliary’s name in PoolCop. On a PoolCop fitted with auxiliary modules, Auxiliary 1 to Auxiliary 15 match the channels of the first module and Auxiliary 16 to Auxiliary 30 those of the second. Without a module, Auxiliary 1 to Auxiliary 16 match channels 1 to 16.

Alert 1 to Alert 5 carry one number per active alarm:

ValueAlarm
0Empty slot
1PressureLowPump1
2PHLow
3FCHigh
100 to 255Other PoolCop code, numbered from its name

The Value column shows the PoolCop code followed by its number, for example PHLow (2).

PoolCop Cloud commands received from the KNX bus

Section titled “PoolCop Cloud commands received from the KNX bus”
NameKeyDPTAccepted values
Pump ON / OFF, Pump 2 ON / OFFpumpOnOff, pump2OnOff1.0011: on; 0: off
Pump speed, Pump 2 speedpumpSpeed, pump2Speed5.0100 to 8; any other value is not passed on
Pump forced, Pump 2 forcedpumpForced, pump2Forced5.0100: NotForced; 1: Forced24H; 2: Forced48H; 3: Forced72H; any other value is not passed on
Position of the valve, Pump 2 valve positionvalvePosition, pump2ValvePosition5.0100 to 5, as in the coded value table
Auxiliary 1 to Auxiliary 30aux1 to aux301.0011: on; 0: off
Jet stream on/offjetStreamOnOff1.0011: on; 0: off
Heating setpointsetHeatingSetpoint9.001heating setpoint
Clear all alarmsclearAllAlarms1.001any telegram

Only send values 0 to 5 for the valve: any other value requests the Filter position. Clear all alarms clears the alarms at every telegram received, whatever its value. Jet stream on/off is not passed on if the PoolCop reports that the jet stream is not installed. The Heating setpoint command applies to the first auxiliary that controls heating.

PoolCop Cloud accepts one request per second for a given API key: Pool’nX queues the commands. It then waits for the PoolCop to take them into account, up to about two minutes, then reads the statuses again. If PoolCop Cloud reports too many requests, Pool’nX resends the command once, 11 seconds later.

The PoolCop (legacy) type offers a shorter table:

  • statuses: water and air temperatures, Pressure (14.066, kPa), pH, ORP, Battery voltage, Water level, pump, valve, Auxiliary 1 to Auxiliary 6, pH, ORP and heating setpoints, Auto Add Water, maintenance dates, Pool connected to the network, Alert, Alert number and Alert 1 to Alert 5;
  • commands: Auxiliary 1 to Auxiliary 6, Pump ON / OFF, Position of the valve, Pump speed and Heating setpoint.

For Auxiliary 1 to Auxiliary 6 and Pump ON / OFF, the value received is not passed on: each telegram sends the same command to the PoolCop. Check the resulting state in the statuses, read again 5 seconds after each command.

  1. Send a test command, for example 1 (example) on the Pump ON / OFF address.
  2. In Pool Commands, check Value and Last event.
  3. In Pool Status, Pump Status changes to 1 once the command has been taken into account.

If a message appears in Value, see the KNX commands and Pool’nX troubleshooting.

French labels: Température de l’eau, Status de la pompe, Vitesse de la pompe, Position de la valve, État de marche de la pompe, Mode de filtration de la pompe, Niveau d’eau, Auxiliaire 1, Nombre d’alerte, Pompe ON / OFF, Forçage pompe, Nage à contre-courant marche/arrêt, Consigne de chauffage, Consigne chauffage, Effacer toutes les alarmes.